Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 10, 2019, 06:30 AM
  • B 1530_B 1435 _09092019_234535.mp4

Date
09/09/2019
W/O
787657
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01126
PipeID
P25149
Time
11:30 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6927
Sewer Name
B JOINT OUTFALL B - UNIT 6J
City
PASADENA
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
03
Purpose
Routine Assessment
Project
WO_787657_TV30028_SEP2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
B 1530
Downstream MH
B 1435
Dir. of Survey
Downstream
Length Surveyed
258.1 ft.
Total Length
258.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2I00
O&M Rating
100
Overall Index
2
Overall Quick
Overall Rating
100
Pipe schematic from manhole B 1530 to B 1435
MH: B 1530MH: B 1435downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 15304.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start37.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"256.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish258.1 ft. AMH - Downstream Manhole, Survey Ends - B 1435

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    4.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWL
4.9DAGS
0MWM
37.9TB
0AMHB 1530
258.1AMHB 1435
256.6DAGS

Properties (6)

additional_info
SC378525
custom_field_two
4
customer
LACSD
datetime
2019-09-09T23:30:00-07:00
documentation
PROPIPE
is_lateral_inspection
false