B 1412_B 1411 _09062019_013154.mp4
3.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
4.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
16.6 ft. - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES
30 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES
32.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
203.1 ft. - Roots Medium Joint, from 03 to 09 o'clock, 15 %, within 8 inches of joint: YESR, Start
236.5 ft. - Roots Medium Joint, from 03 to 09 o'clock, 15 %, within 8 inches of joint: YESR, Start
| Distance | Code | Observation |
|---|---|---|
| 271.7 | DAGS | — |
| 236.5 | RMJ | — |
| 271.7 | RMJ | — |
| 258.4 | TFC | — |
| 205 | TB | — |
| 107.5 | TFC | — |
| 157.7 | TFC | — |
| 59.2 | TFC | — |
| 16.6 | RFJ | — |
| 203.1 | RMJ | — |
| 0 | MWM | — |
| 155.3 | TF | — |
| 260.7 | TFC | — |
| 271.7 | CM | — |
| 4.5 | CM | — |
| 0 | AMH | B 1412 |
| 5.8 | TFC | — |
| 3.8 | DAGS | — |
| 56.6 | TF | — |
| 208.5 | RMJ | — |
| 273.3 | AMH | B 1411 |
| 0 | MWL | — |
| 203.1 | TFC | — |
| 30 | FL | — |
| 32.6 | FM | — |
| 104.6 | TFC | — |