- Date
- 09/17/2019
- W/O
- 787657
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z01126
- PipeID
- P25075
- Time
- 2:48 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6933
- Sewer Name
- B JOINT OUTFALL B - UNIT 6J
- City
- PASADENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- WO_787657_TV30028_SEP2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- B 1363
- Downstream MH
- B 1362
- Dir. of Survey
- Downstream
- Length Surveyed
- 159.5 ft.
- Total Length
- 159.5 ft.
- Structural Index
- 2
- Structural Quick
- 3122
- Structural Rating
- 7
- O&M Index
- 2
- O&M Quick
- 2E00
- O&M Rating
- 64
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 71
Pipe schematic from manhole B 1363 to B 1362 Observation photos (5)

3.5 ft. - Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

3.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

21.2 ft. - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

21.2 ft. - Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: NO

76.4 ft. - Roots Tap Joint, at 08 o'clock, 5 %, within 8 inches of joint: YESR