- Date
- 11/18/2019
- W/O
- 0792641
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00183
- PipeID
- P26737
- Time
- 9:26 AM
- Certificate
- U-415-060624039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- CLIP ONLY
- Sewer Name
- H JOINT OUTFALL H - UNIT 7B
- City
- INDUSTRY
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 35
- Purpose
- Routine Assessment
- Project
- 20191118DF_JOINT_OUTFALL_H_UNIT_7B
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 45 in.
- Upstream MH
- H 0510
- Downstream MH
- H 0509A
- Dir. of Survey
- Downstream
- Length Surveyed
- 362.8 ft.
- Total Length
- 362.8 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 0
- Overall Quick
- —
- Overall Rating
- 0
Pipe schematic from manhole H 0510 to H 0509A Observation photos (5)

0 ft. - Upstream Manhole, Survey Begins - 9:20 AM

2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 85% MAG

84.9 ft. - General Photograph

202.7 ft. - General Photograph

333.8 ft. - General Photograph