- Date
- 11/15/2019
- W/O
- 0798462
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00716
- PipeID
- P14823
- Time
- 3:02 AM
- Certificate
- 1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1310
- Sewer Name
- 18 WORSHAM CREEK TRUNK
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- 20191114MDM_WORSHAM_CREEK_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Upstream MH
- 18 0971A
- Downstream MH
- 18 0986
- Dir. of Survey
- Downstream
- Length Surveyed
- 194.7 ft.
- Total Length
- 194.7 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 3
- O&M Quick
- 3511
- O&M Rating
- 16
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 16
Pipe schematic from manhole 18 0971A to 18 0986 Observation photos (2)

143.7 ft. - Roots Medium Connection, from 09 to 12 o'clock, 10 %, within 8 inches of joint: NO

194.3 ft. - Roots Medium Connection, from 08 to 11 o'clock, 15 %, within 8 inches of joint: NO