Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2018, 10:33 AM
  • 15 0896_15 0895 _26042018_035042.mp4

Date
04/26/2018
W/O
695662
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00599
PipeID
P12690
Time
3:33 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5577
Sewer Name
15 CALIFORNIA AVENUE TRUNK
City
MONROVIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
05
Purpose
Routine Assessment
Project
WO_695662_TV15182_APR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0896
Downstream MH
15 0895
Dir. of Survey
Downstream
Length Surveyed
261.1 ft.
Total Length
261.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0896 to 15 0895
MH: 15 0896MH: 15 0895downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 15 08960 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start66.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4"150.7 ft. TBI - Tap Break-In Intruding, at 11 o'clock, -, #v, within 8 inches of joint: NO, 4", 1"158 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"200.4 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"258.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish261.1 ft. AMH - Downstream Manhole, Survey Ends - 15 0895261.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 11 o'clock, -, #v, within 8 inches of joint: NO, 4", 1"

    150.7 ft. - Tap Break-In Intruding, at 11 o'clock, -, #v, within 8 inches of joint: NO, 4", 1"

Observations (13)

DistanceCodeObservation
261.1AMH15 0895
0MGOCOCKROACHES IN MANHOLE
258.6SAP
0AMH15 0896
0MWL
0MWM
2SAP
158TBA
200.4TBA
66.7TB
261.1MGOCOCKROACHES IN MANHOLE
150.7TBI
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK

Properties (6)

additional_info
SC358537
custom_field_two
2
customer
LACSD
datetime
2018-04-26T03:33:32-07:00
documentation
PRO PIPE
is_lateral_inspection
false