Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 25, 2018, 10:09 AM
  • 15 0883_15 0882 _25042018_032034.mp4

Date
04/25/2018
W/O
695662
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00599
PipeID
P12676
Time
3:09 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5576
Sewer Name
15 CALIFORNIA AVENUE TRUNK
City
MONROVIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
05
Purpose
Routine Assessment
Project
WO_695662_TV15182_APR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0883
Downstream MH
15 0882
Dir. of Survey
Downstream
Length Surveyed
303.6 ft.
Total Length
303.6 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
180
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
180
Pipe schematic from manhole 15 0883 to 15 0882
MH: 15 0883MH: 15 0882downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 08830 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start61.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"67.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"131.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"147.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"183.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"223.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"244.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"303.6 ft. MGO - General Observation - CAPPED CONNECTION AT MH 3 AND 9 O'CLOCK303.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0882303.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish303.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
67.6TFC
0MWL
303.6MGOCAPPED CONNECTION AT MH 3 AND 9 O'CLOCK
147.1TFC
0AMH15 0883
303.6AMH15 0882
303.6SAP
183.8TFC
223.7TFC
303.6MGOCOCKROACHES IN MANHOLE
2SAP
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
131.3TFC
0MWM
61.2TFA
244.6TFC

Properties (6)

additional_info
SC358536
custom_field_two
2
customer
LACSD
datetime
2018-04-25T03:09:14-07:00
documentation
PRO PIPE
is_lateral_inspection
false