Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2019, 09:08 AM
  • 18 0375_18 0374 _03182019_022626.mp4

Date
03/18/2019
W/O
755957
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00690
PipeID
P14209
Time
2:08 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6478
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Routine Assessment
Project
RFIR_WO_755957_TV18095_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0375
Downstream MH
18 0374
Dir. of Survey
Downstream
Length Surveyed
352.5 ft.
Total Length
352.5 ft.
Structural Index
4
Structural Quick
4M00
Structural Rating
276
O&M Index
2
O&M Quick
2M00
O&M Rating
140
Overall Index
3
Overall Quick
Overall Rating
416
Pipe schematic from manhole 18 0375 to 18 0374
MH: 18 0375MH: 18 0374downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 03750 ft. MWL - Water Level, 15 %of cross sectional area1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"68.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"141.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"242.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"349 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish352 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish352.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED352.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0374352.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
39.7TF
352.5MGOCONNECTION AT MH 9 O'CLOCK CAPPED
68.5TBA
141.2TFA
352DAGS
352.5AMH18 0374
6FM
349FM
0MWM
242.9TFC
1DAGS
352.5MGOCONNECTION AT MH 3 O'CLOCK CAPPED
0AMH18 0375
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-03-18T02:08:23-07:00
documentation
PROPIPE
is_lateral_inspection
false