Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 23, 2019, 11:48 AM
  • 01 0348_01 0347_01232019_224636.mp4

Date
01/23/2019
W/O
745391
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00215
PipeID
P00829
Time
3:48 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5344
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_745391_TV01270_JAN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0354
Downstream MH
01 0355
Dir. of Survey
Upstream
Length Surveyed
192.6 ft.
Total Length
192.6 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
3
O&M Quick
4123
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 01 0354 to 01 0355
MH: 01 0354MH: 01 0355upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 03550.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES37.6 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES192.6 ft. AMH - Downstream Manhole, Survey Begins - 01 0354192.6 ft. MWM - Water Mark, 50 %of cross sectional area192.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start192.6 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    155 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
192DAGS
0AMH01 0354
192DAE
0MWM
0DAGS
0MWL
192.6AMH01 0355
155FM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-01-23T03:48:46-08:00
documentation
PROPIPE
is_lateral_inspection
false