Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2018, 07:47 PM
  • 15_02 1654_02 1653_Shot_SI_TapeLocation_POST_26042018_124759.mpg

Date
04/26/2018
W/O
200326
Weather
Dry
Operator/Surveyor
OSCAR VILLARREAL
Sewer ID
Z00289
PipeID
P18809
Time
12:47 PM
Certificate
U-1113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
01
Sewer Name
MONTERREY PARK CA.
City
MONTERREY PARK CA.
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Post-Rehabilitation Survey
Project
MONTEREY_PARK_RELIEF_TRUNK_REHABILITATION
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
02 1654
Downstream MH
02 1653
Dir. of Survey
Downstream
Length Surveyed
167.1 ft.
Total Length
167.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1654 to 02 1653
MH: 02 1654MH: 02 1653downstream0 ft. MWL - Water Level, 0 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - mh 16540 ft. MWL - Water Level, 5 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 165493 ft. TFA - Tap Factory Made Active, at 12 o'clock, 4", within 8 inches of joint: YES94 ft. TFA - Tap Factory Made Active, at 12 o'clock, 4", within 8 inches of joint: YES166.5 ft. AMH - Downstream Manhole, Survey Ends - MH 1653167.1 ft. AMH - Downstream Manhole, Survey Ends - mh 1653

Observations (8)

DistanceCodeObservation
93TFA
0MWL
167.1AMHmh 1653
0AMHmh 1654
166.5AMHMH 1653
0MWL
0AMHMH 1654
94TFA

Properties (3)

customer
LACSD
datetime
2018-04-26T12:47:48-07:00
is_lateral_inspection
false