Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 23, 2018, 01:23 PM
  • 4_02 1796_02 1795_Shot_SI_TapeLocation_POST_23042018_165007.mpg

Date
04/23/2018
W/O
200326
Weather
Dry
Operator/Surveyor
OSCAR VILLARREAL
Sewer ID
Z00292
PipeID
P04141
Time
6:23 AM
Certificate
U-1113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
01
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
MONTERREY PARK CA.
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Pre-Rehabilitation Survey
Project
MONTEREY_PARK_RELIEF_TRUNK_REHABILITATION
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Upstream MH
02 1796
Downstream MH
02 1795
Dir. of Survey
Downstream
Length Surveyed
283 ft.
Total Length
283 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1796 to 02 1795
MH: 02 1796MH: 02 1795downstream0 ft. MWL - Water Level, 5 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 17960 ft. AMH - Upstream Manhole, Survey Begins - mh 17960 ft. MWL - Water Level, 5 % of cross sectional area6.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES8.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES36.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES38.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES45.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES48 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES60.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES62.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES81.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES100.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES119.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES122.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES122.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES125 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES164.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES166.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES167.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES169.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES205.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES208.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES211.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES214.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES229.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES232 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES241.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES243.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES280.7 ft. AMH - Downstream Manhole, Survey Ends - mh 1795283 ft. AMH - Downstream Manhole, Survey Ends - MH 1795

Observations (32)

DistanceCodeObservation
38.7TFA
169.4TFA
232TFA
8.7TFA
62.6TFA
48TFA
122.1TFA
214.3TFA
125TFA
208.9TFA
243.2TFA
0MWL
0AMHMH 1796
100.9TFA
283AMHMH 1795
166.3TFA
229.4TFA
122.8TFA
0AMHmh 1796
60.5TFA
81.2TFA
241.3TFA
36.7TFA
45.6TFA
0MWL
167.3TFA
6.8TFA
280.7AMHmh 1795
205.9TFA
119.8TFA
211.7TFA
164.4TFA

Properties (3)

customer
LACSD
datetime
2018-04-23T06:23:20-07:00
is_lateral_inspection
false