Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 16, 2018, 02:48 PM
  • 13_02 1805_02 1804_Shot_SI_TapeLocation_POST_16042018_164555.mpg

Date
04/16/2018
W/O
200326
Weather
Dry
Operator/Surveyor
OSCAR VILLARREAL
Sewer ID
Z00292
PipeID
P04150
Time
7:48 AM
Certificate
--1113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
01
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
MONTERREY PARK CA.
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Pre-Rehabilitation Survey
Project
MONTEREY_PARK_RELIEF_TRUNK_REHABILITATION
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Upstream MH
02 1805
Downstream MH
02 1804
Dir. of Survey
Downstream
Length Surveyed
193.8 ft.
Total Length
193.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1805 to 02 1804
MH: 02 1805MH: 02 1804downstream0 ft. AMH - Upstream Manhole, Survey Begins - MH 18050 ft. MWL - Water Level, 5 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 18050 ft. MWL - Water Level, 5 % of cross sectional area33 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES36 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES36.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES38.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES65.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES68.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES77.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES79.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES118.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES121.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES121.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES123.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES136.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES138.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES163.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES165.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES193.6 ft. AMH - Downstream Manhole, Survey Ends - MH 1804193.8 ft. AMH - Downstream Manhole, Survey Ends - MH 1804

Observations (22)

DistanceCodeObservation
0AMHMH 1805
36.1TFA
121.8TFA
193.8AMHMH 1804
77.6TFA
65.5TFA
0MWL
163.3TFA
136.6TFA
118.9TFA
33TFA
36TFA
121.5TFA
0AMHMH 1805
193.6AMHMH 1804
0MWL
68.3TFA
123.8TFA
165.2TFA
38.2TFA
138.9TFA
79.8TFA

Properties (3)

customer
LACSD
datetime
2018-04-16T07:48:25-07:00
is_lateral_inspection
false