Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 18, 2018, 01:17 PM
  • 10_02 1802_02 1801_Shot_SI_TapeLocation_POST_19042018_110050.mpg

Date
04/18/2018
W/O
200326
Weather
Dry
Operator/Surveyor
OSCAR VILLARREAL
Sewer ID
Z00292
PipeID
P04147
Time
6:17 AM
Certificate
U-1113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
01
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
MONTERREY PARK CA.
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Pre-Rehabilitation Survey
Project
MONTEREY_PARK_RELIEF_TRUNK_REHABILITATION
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Upstream MH
02 1802
Downstream MH
02 1801
Dir. of Survey
Downstream
Length Surveyed
280.5 ft.
Total Length
283.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1802 to 02 1801
MH: 02 1802MH: 02 1801downstream0 ft. AMH - Upstream Manhole, Survey Begins - MH 18020 ft. MWL - Water Level, 5 % of cross sectional area0 ft. MWL - Water Level, 0 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 18026.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES9.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES39.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES42.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES51.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES54.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES81.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES84.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES90 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES92.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES110.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES113.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES125.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES128.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES164.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES166.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES167.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES169.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES202.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES205.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES206.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES208.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES226.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES229.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES230 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES233 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES280.5 ft. AMH - Downstream Manhole, Survey Ends - MH 1801283.5 ft. AMH - Downstream Manhole, Survey Ends - MH 1801

Observations (32)

DistanceCodeObservation
0AMHMH 1802
202.8TFA
205.6TFA
125.6TFA
226.6TFA
81.1TFA
0MWL
229.5TFA
280.5AMHMH 1801
6.9TFA
164.1TFA
110.6TFA
167.2TFA
90TFA
39.5TFA
51.5TFA
206.4TFA
92.9TFA
42.2TFA
208.5TFA
230TFA
113.4TFA
283.5AMHMH 1801
84.2TFA
0MWL
166.7TFA
0AMHMH 1802
128.5TFA
9.5TFA
169.6TFA
233TFA
54.5TFA

Properties (3)

customer
LACSD
datetime
2018-04-18T06:17:56-07:00
is_lateral_inspection
false