Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 5, 2018, 08:47 PM
  • 2_02 1794_02 1793_Shot_SI_TapeLocation_POST_24042018_164910.mpg

Date
03/05/2018
W/O
200326
Weather
Dry
Operator/Surveyor
OSCAR VILLARREAL
Sewer ID
Z00292
PipeID
P04139
Time
12:47 PM
Certificate
U-113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
01
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
MONTERREY PARK CA.
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Pre-Rehabilitation Survey
Project
MONTEREY_PARK_RELIEF_TRUNK_REHABILITATION
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Upstream MH
02 1794
Downstream MH
02 1793
Dir. of Survey
Downstream
Length Surveyed
322.4 ft.
Total Length
325.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 1794 to 02 1793
MH: 02 1794MH: 02 1793downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 17940 ft. MWL - Water Level, 0 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 17947.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"8 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES22.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"25 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES43.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"45.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES61.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"63 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES90.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"92.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES102.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"104.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES129.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"131 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES140.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"142.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES176.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"178.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES182.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"184.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES212 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"215.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES217.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"220 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES262.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"264.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES268.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"270.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES274.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"276.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES280.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"282.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES319.2 ft. TFB - Tap Factory Made Abandoned, at 06 o'clock, -, within 8 inches of joint: YES, 6"322.4 ft. ACOM - Cleanout Mainline, Survey Ends - MH 1793323.1 ft. TFA - Tap Factory Made Active, at 06 o'clock, 4", within 8 inches of joint: YES325.2 ft. AMH - Downstream Manhole, Survey Ends - MH 1793

Observations (40)

DistanceCodeObservation
90.7TFA
43.3TFA
0MWL
182.4TFA
319.2TFB
274.1TFA
212TFA
129.3TFA
217.9TFA
61.4TFA
102.8TFA
262.7TFA
280.2TFA
22.4TFA
176.2TFA
268.6TFA
7.7TFA
322.4ACOMMH 1793
0AMHMH 1794
140.8TFA
270.6TFA
215.9TFA
63TFA
45.4TFA
8TFA
131TFA
0MWL
220TFA
92.7TFA
323.1TFA
276.2TFA
184.1TFA
0AMHMH 1794
178.3TFA
325.2AMHMH 1793
25TFA
142.9TFA
104.3TFA
264.2TFA
282.3TFA

Properties (3)

customer
LACSD
datetime
2018-03-05T12:47:04-08:00
is_lateral_inspection
false