Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 19, 2018, 02:27 PM
  • 7_02 1799_02 1798_Shot_SI_TapeLocation_POST_19042018_170245.mpg

Date
04/19/2018
W/O
200326
Weather
Operator/Surveyor
OSCAR VILLARREAL
Sewer ID
Z00292
PipeID
P04144
Time
7:27 AM
Certificate
U-113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
01
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
MONTERREAY PARK CA.
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Pre-Rehabilitation Survey
Project
MONTEREY_PARK_RELIEF_TRUNK_REHABILITATION
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Upstream MH
02 1799
Downstream MH
02 1798
Dir. of Survey
Downstream
Length Surveyed
278.2 ft.
Total Length
279.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1799 to 02 1798
MH: 02 1799MH: 02 1798downstream0 ft. MWL - Water Level, 5 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 17990 ft. AMH - Upstream Manhole, Survey Begins - mh 17990 ft. MWL - Water Level, 5 % of cross sectional area31.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES31.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES40.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES41.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES75.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES77.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES78.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES80.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES116.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES117.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES120.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES120.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES158.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES159 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES161.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES163.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES200.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES201.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES203.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES204.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES215.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES216.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, 4", within 8 inches of joint: YES248 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES250.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, 4", within 8 inches of joint: YES278.2 ft. AMH - Downstream Manhole, Survey Ends - MH 1798279.8 ft. AMH - Downstream Manhole, Survey Ends - mh 1798

Observations (30)

DistanceCodeObservation
31.3TFA
117.5TFA
203.4TFA
159TFA
248TFA
40.2TFA
278.2AMHMH 1798
200.5TFA
0MWL
78.8TFA
215.3TFA
0AMHMH 1799
161.9TFA
120.4TFA
75.8TFA
163.9TFA
120.9TFA
0AMHmh 1799
0MWL
80.6TFA
41.3TFA
31.4TFA
201.2TFA
279.8AMHmh 1798
77.2TFA
204.8TFA
216.6TFA
116.6TFA
250.3TFA
158.2TFA

Properties (3)

customer
LACSD
datetime
2018-04-19T07:27:56-07:00
is_lateral_inspection
false