Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 5, 2019, 06:00 AM
  • 18 0803_18 0802A _11042019_221633.mp4

Date
11/04/2019
W/O
792842
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14663
Time
10:00 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6326
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
SANTA FE SPRINGS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_792842_TV18197_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0803
Downstream MH
18 0802A
Dir. of Survey
Downstream
Length Surveyed
325.6 ft.
Total Length
325.6 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
256
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
256
Pipe schematic from manhole 18 0803 to 18 0802A
MH: 18 0803MH: 18 0802Adownstream0 ft. MGO - General Observation - CONNECTION AT 9 O'CLOCK0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08035.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start325.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0802A325.6 ft. MGO - General Observation - CONNECTION AT 9 O'CLOCK325.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Upstream Manhole, Survey Begins - 18 0803

    0 ft. - Upstream Manhole, Survey Begins - 18 0803

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MGOCONNECTION AT 9 O'CLOCK
325.6AMH18 0802A
0MWM
0MWL
5.3FM
325.6MGOCONNECTION AT 9 O'CLOCK
0AMH18 0803
325.6FM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-11-04T22:00:43-08:00
documentation
PROPIPE
is_lateral_inspection
false