- Date
- 11/04/2019
- W/O
- 792842
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00706
- PipeID
- P14660
- Time
- 10:52 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6326
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
- City
- SANTA FE SPRINGS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_792842_TV18197_OCT2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0800A
- Downstream MH
- 18 0800
- Dir. of Survey
- Downstream
- Length Surveyed
- 42 ft.
- Total Length
- 42 ft.
- Structural Index
- 3
- Structural Quick
- 4825
- Structural Rating
- 42
- O&M Index
- 2
- O&M Quick
- 2800
- O&M Rating
- 16
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 58
Pipe schematic from manhole 18 0800A to 18 0800 Observation photos (3)

3.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

5.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

17.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start