Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2018, 08:59 AM
  • 05 0112_05 0111 _12142018_013413.mp4

Date
12/14/2018
W/O
740131
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05402
Time
12:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6249
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHRONE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_740015_TV05147_DEC2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
05 0112
Downstream MH
05 0111
Dir. of Survey
Downstream
Length Surveyed
331.2 ft.
Total Length
331.2 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
195
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
195
Pipe schematic from manhole 05 0112 to 05 0111
MH: 05 0112MH: 05 0111downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 01120 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2.3 ft. MGO - General Observation - MAG COAT3.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start329.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish331.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK331.2 ft. AMH - Downstream Manhole, Survey Ends - 05 0111331.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
331.2MGOCONNECTION AT MH 9 O'CLOCK
331.2AMH05 0111
329.8SAP
3.5SAP
331.2MGOCONNECTION AT MH 3 O'CLOCK
0AMH05 0112
0MWM
0MWL
2.3MGOMAG COAT

Properties (6)

additional_info
SC365482
custom_field_two
3
customer
LACSD
datetime
2018-12-14T00:59:55-08:00
documentation
PROPIPE
is_lateral_inspection
false