Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2018, 05:49 AM
  • 05 0124_05 0123 _12132018_220013.mp4

Date
12/13/2018
W/O
740131
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05414
Time
9:49 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6249
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHRONE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_740015_TV05147_DEC2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
05 0124
Downstream MH
05 0123
Dir. of Survey
Downstream
Length Surveyed
323.6 ft.
Total Length
323.6 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
192
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
192
Pipe schematic from manhole 05 0124 to 05 0123
MH: 05 0124MH: 05 0123downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 01240 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT323.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish323.6 ft. AMH - Downstream Manhole, Survey Ends - 05 0123323.6 ft. MGO - General Observation - CAPPED LATERAL 3 O'CLOCK @ MH323.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
2.1SAV
323.6AMH05 0123
0AMH05 0124
0MWL
2.1MGOMAG COAT
323.5SAV
323.6MGOCAPPED LATERAL 3 O'CLOCK @ MH
323.6MGOCONNECTION AT MH 9 O'CLOCK
0MWM

Properties (6)

additional_info
SC365482
custom_field_two
3
customer
LACSD
datetime
2018-12-13T21:49:49-08:00
documentation
PROPIPE
is_lateral_inspection
false