Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 20, 2018, 07:17 AM
  • 05 0096_05 0095 _12192018_232804.mp4

Date
12/19/2018
W/O
740131
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05386
Time
11:17 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6253
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHRONE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_740015_TV05147_DEC2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
05 0096
Downstream MH
05 0095
Dir. of Survey
Downstream
Length Surveyed
330.3 ft.
Total Length
330.3 ft.
Structural Index
4
Structural Quick
5L3L
Structural Rating
523
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
523
Pipe schematic from manhole 05 0096 to 05 0095
MH: 05 0096MH: 05 0095downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 00960 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - CAPPED LATERAL 3 O'CLOCK @ MH2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.9 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SPORADICALLY THROUGHOUT330.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK330.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.3 ft. AMH - Downstream Manhole, Survey Ends - 05 0095

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SPORADICALLY THROUGHOUT

    2.9 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SPORADICALLY THROUGHOUT

Observations (11)

DistanceCodeObservation
330.3MGOCONNECTION AT MH 9 O'CLOCK
0MWM
0AMH05 0096
330.3SAP
330.3AMH05 0095
330.1SRV
2SAP
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
0MGOCAPPED LATERAL 3 O'CLOCK @ MH
2.9SRVSPORADICALLY THROUGHOUT

Properties (6)

additional_info
SC365486
custom_field_two
2
customer
LACSD
datetime
2018-12-19T23:17:08-08:00
documentation
PROPIPE
is_lateral_inspection
false