Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 21, 2016, 09:07 AM
  • 05 2076_05 2075_20160121_010739.mp4

Date
01/21/2016
W/O
536429
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00432
PipeID
P07220
Time
1:07 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3119
Sewer Name
05 DISTRICT #5 MAIN RELIEF TRUNK
City
HAWTHORNE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
WO_536429_TV05014_DEC2015
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Upstream MH
05 2076
Downstream MH
05 2075
Dir. of Survey
Downstream
Length Surveyed
393.8 ft.
Total Length
393.8 ft.
Structural Index
3
Structural Quick
513N
Structural Rating
390
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
390
Pipe schematic from manhole 05 2076 to 05 2075
MH: 05 2076MH: 05 2075downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 20762 ft. MGO - General Observation - MAGNESIUM H.O. START3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start4 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SPORADICALLY THROUGHOUT32 ft. SRV - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: YES390 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish391 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish391.7 ft. MGO - General Observation - END MAG393.8 ft. AMH - Downstream Manhole, Survey Ends - 05 2075

Observations (10)

DistanceCodeObservation
32SRV
393.8AMH05 2075
2MGOMAGNESIUM H.O. START
390SSS
391SAV
4SAVSPORADICALLY THROUGHOUT
391.7MGOEND MAG
0MWL
0AMH05 2076
3SSS

Properties (6)

additional_info
SC225504
custom_field_two
3
customer
LACSD
datetime
2016-01-21T01:07:05-08:00
documentation
PRO-PIPE
is_lateral_inspection
false