- Date
- 01/07/2016
- W/O
- 536429
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00432
- PipeID
- P05581
- Time
- 11:31 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3068
- Sewer Name
- 05 DISTRICT #5 MAIN RELIEF TRUNK
- City
- HAWTHORNE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_536429_TV05014_DEC2015
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Upstream MH
- 05 0366
- Downstream MH
- 05 0365
- Dir. of Survey
- Downstream
- Length Surveyed
- 329.6 ft.
- Total Length
- 329.6 ft.
- Structural Index
- 4
- Structural Quick
- 5434
- Structural Rating
- 36
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 40
Pipe schematic from manhole 05 0366 to 05 0365 Observation photos (6)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

67.7 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES

67.9 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

136.9 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES

147.2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

153.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start