- Date
- 01/11/2016
- W/O
- 536429
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00432
- PipeID
- P05559
- Time
- 4:09 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3069
- Sewer Name
- 05 DISTRICT #5 MAIN RELIEF TRUNK
- City
- HAWTHORNE
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_536429_TV05014_DEC2015
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- 05 0345
- Downstream MH
- 05 0344
- Dir. of Survey
- Downstream
- Length Surveyed
- 496 ft.
- Total Length
- 496 ft.
- Structural Index
- 3
- Structural Quick
- 5O3S
- Structural Rating
- 890
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 894
Pipe schematic from manhole 05 0345 to 05 0344 Observation photos (3)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

101.1 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SPORADICALLY THROUGHOUT