Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 14, 2019, 09:00 AM
  • 16 0293_16 0292_10142019_013656.mp4

Date
10/14/2019
W/O
792841
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00643
PipeID
P13343
Time
2:00 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6965
Sewer Name
16 ALMANSOR STREET EXTENSION TRUNK
City
MONTEREY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
25
Purpose
Routine Assessment
Project
RFIR_WO_792841_TV16123_OCT2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
16 0293
Downstream MH
16 0292
Dir. of Survey
Downstream
Length Surveyed
220.8 ft.
Total Length
220.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
3222
O&M Rating
11
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 16 0293 to 16 0292
MH: 16 0293MH: 16 0292downstream0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 02932 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start28 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - DEBRIS33 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES53.8 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS121 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"127.4 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - DEBRIS219.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish219.5 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish220.8 ft. AMH - Downstream Manhole, Survey Ends - 16 0292

Observation photos (6)

  • Vermin Cockroach

    0 ft. - Vermin Cockroach

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Settled Other,  15 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES - DEBRIS

    28 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - DEBRIS

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    33 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Deposits Settled Other,  15 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - DEBRIS

    53.8 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS

Observations (15)

DistanceCodeObservation
28DSZDEBRIS
33FS
2DAGS
0VC
0MWM
219.5DAGS
121TB
0MGOCONNECTION AT MH 9 O'CLOCK
53.8DSZDEBRIS
220.8AMH16 0292
0MWL
219.5DAE
2DAE
127.4DSZDEBRIS
0AMH16 0293

Properties (6)

additional_info
SC378589
custom_field_two
3
customer
LACSD
datetime
2019-10-14T02:00:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false