- Date
- 10/14/2019
- W/O
- 792841
- Weather
- Dry
- Operator/Surveyor
- J. VARGAS
- Sewer ID
- Z00643
- PipeID
- P13341
- Time
- 2:42 AM
- Certificate
- U-209-8149
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6965
- Sewer Name
- 16 ALMANSOR STREET EXTENSION TRUNK
- City
- MONTEREY PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 25
- Purpose
- Routine Assessment
- Project
- RFIR_WO_792841_TV16123_OCT2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 16 0291
- Downstream MH
- 16 0290
- Dir. of Survey
- Downstream
- Length Surveyed
- 452.3 ft.
- Total Length
- 452.3 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2a11
- O&M Rating
- 343
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 343
Pipe schematic from manhole 16 0291 to 16 0290 Observation photos (3)

0 ft. - Upstream Manhole, Survey Begins - 16 0291

2.3 ft. - Deposits Attached grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

47.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start