Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 7, 2019, 07:05 AM
  • 16 0572_16 0571 _11062019_231557.mp4

Date
11/06/2019
W/O
792799
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00659
PipeID
P13623
Time
11:05 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7112
Sewer Name
16 LAMANDA PARK TRUNK
City
PASADENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
WO_792799_TV16077_OCT2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
22 in.
Width
22 in.
Upstream MH
16 0572
Downstream MH
16 0571
Dir. of Survey
Downstream
Length Surveyed
257.4 ft.
Total Length
257.4 ft.
Structural Index
4
Structural Quick
5G3I
Structural Rating
358
O&M Index
2
O&M Quick
2S00
O&M Rating
200
Overall Index
3
Overall Quick
Overall Rating
558
Pipe schematic from manhole 16 0572 to 16 0571
MH: 16 0572MH: 16 0571downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 05722 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start14.2 ft. RFB - Roots Fine Barrell, from 08 to 04 o'clock, within 8 inches of joint: YES, Start20.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"36.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"52.1 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES62.4 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start80 ft. RTJ - Roots Tap Joint, from 10 to 02 o'clock, 5 %, within 8 inches of joint: YESR92.1 ft. SRV - Surface Reinforcement Visible, from 08 to 02 o'clock, within 8 inches of joint: YES113.2 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"133.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6" - EXPOSED AGGREGATE162 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS182.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"214.6 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"233 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"255.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish255.7 ft. RFB - Roots Fine Barrell, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish255.7 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish255.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish257.4 ft. AMH - Downstream Manhole, Survey Ends - 16 0571

Observation photos (8)

  • Upstream Manhole, Survey Begins - 16 0572

    0 ft. - Upstream Manhole, Survey Begins - 16 0572

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Roots Fine Barrell, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    14.2 ft. - Roots Fine Barrell, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

    52.1 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    62.4 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • Roots Tap Joint, from 10 to 02 o'clock, 5 %, within 8 inches of joint: YESR

    80 ft. - Roots Tap Joint, from 10 to 02 o'clock, 5 %, within 8 inches of joint: YESR

  • Surface Reinforcement Visible, from 08 to 02 o'clock, within 8 inches of joint: YES

    92.1 ft. - Surface Reinforcement Visible, from 08 to 02 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
214.6TFA
0MWL
36.3TFC
0MWM
255.7DAGS
2SAP
233TFA
255.7RFB
0AMH16 0572
133.8TFCEXPOSED AGGREGATE
255.7SRV
162TFCROOTS
52.1SRV
257.4AMH16 0571
20.2TFC
113.2TFA
182.1TFC
62.4SRV
14.2RFB
255.7SAP
2DAGS
80RTJ
92.1SRV

Properties (6)

additional_info
SC378743
custom_field_two
2
customer
LACSD
datetime
2019-11-06T23:05:17-08:00
documentation
PRO PIPE
is_lateral_inspection
false