- Date
- 11/05/2019
- W/O
- 792810
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00706
- PipeID
- P14654
- Time
- 12:45 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6327
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
- City
- SANTA FE SPRINGS
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_792810_TV18182_OCT2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0795
- Downstream MH
- 18 0796
- Dir. of Survey
- Upstream
- Length Surveyed
- 365 ft.
- Total Length
- 365 ft.
- Structural Index
- 4
- Structural Quick
- 4K3E
- Structural Rating
- 329
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 126
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 455
Pipe schematic from manhole 18 0795 to 18 0796 Observation photos (3)

2.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

19.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

211.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start