16 0658_16 0657 _11042019_024350.mp4

0 ft. - Upstream Manhole, Survey Begins - 16 0658
0 ft. - General Observation - COCKROACHES IN MANHOLE
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES
2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES
9.3 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES
9.3 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 10"
9.3 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 8"
9.3 ft. - Survey Abandoned - VIEW OF DOWNLEG OF U/S SIPHON.
| Distance | Code | Observation |
|---|---|---|
| 2 | DAGS | — |
| 0 | MWM | — |
| 0 | AMH | 16 0658 |
| 2 | SAV | — |
| 0 | MGO | ACTIVE CONNECTION AT MH 3 O'CLOCK |
| 9.3 | SAP | — |
| 9.3 | TFD | — |
| 2 | SSS | — |
| 0 | MWL | — |
| 0 | MGO | COCKROACHES IN MANHOLE |
| 9.3 | TFD | — |
| 9.3 | MSA | VIEW OF DOWNLEG OF U/S SIPHON. |