Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2019, 11:00 AM
  • 15 0612A_15 0612A1_11042019_031029.mp4

Date
11/04/2019
W/O
792806
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00601
PipeID
P26624
Time
3:00 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6324
Sewer Name
15 DOUBLE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0612A
Downstream MH
15 0612A1
Dir. of Survey
Downstream
Length Surveyed
150.1 ft.
Total Length
150.1 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
87
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
89
Pipe schematic from manhole 15 0612A to 15 0612A1
MH: 15 0612AMH: 15 0612A1downstream0 ft. MGO - General Observation - CONNECTION AT 3 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 0612A0 ft. MWL - Water Level, 15 %of cross sectional area2.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start43.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"45.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES82.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"126.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"132.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"150 ft. MGO - General Observation - CONNECTION AT 3 O'CLOCK150 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish150.1 ft. AMH - Downstream Manhole, Survey Ends - 15 0612A1

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
43.2TF
132.8TF
0MGOCONNECTION AT 3 O'CLOCK
150.1AMH15 0612A1
2.6SAP
45.2DSZ
0MWM
0AMH15 0612A
82.1TF
150MGOCONNECTION AT 3 O'CLOCK
0MWL
126.5TF
150SAP

Properties (6)

additional_info
SC365761
custom_field_two
2
customer
LACSD
datetime
2019-11-04T03:00:18-08:00
documentation
PROPIPE
is_lateral_inspection
false