- Date
- 10/04/2019
- W/O
- 787618
- Weather
- Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00639
- PipeID
- P13055
- Time
- 2:57 AM
- Certificate
- U-109-7948
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6096
- Sewer Name
- 16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
- City
- SAN CABRIEL
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- RFIR_WO_787618_TV16113_SEP2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Width
- 16 in.
- Upstream MH
- 16 0042
- Downstream MH
- 16 0041
- Dir. of Survey
- Downstream
- Length Surveyed
- 297 ft.
- Total Length
- 297 ft.
- Structural Index
- 3
- Structural Quick
- 4F3K
- Structural Rating
- 318
- O&M Index
- 2
- O&M Quick
- 2K13
- O&M Rating
- 119
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 437
Pipe schematic from manhole 16 0042 to 16 0041 Observation photos (5)

34 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

41.5 ft. - Roots Fine Joint, at 11 o'clock, within 8 inches of joint: YES

41.5 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

52.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

93.4 ft. - Roots Fine Joint, from 11 to 02 o'clock, within 8 inches of joint: YES