Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2019, 09:06 AM
  • 18 0206_18 0205_1192019_023823.mp4

Date
11/09/2019
W/O
0801678
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00695
PipeID
P14031
Time
1:06 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Heavy Cleaning
Media Label
H1305
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
13
Purpose
Maintenance Related
Project
20191107MDM_ORR_AND_DAY_ROAD_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
18 0206
Downstream MH
18 0205
Dir. of Survey
Downstream
Length Surveyed
8.5 ft.
Total Length
8.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
5
O&M Quick
5200
O&M Rating
10
Overall Index
5
Overall Quick
Overall Rating
10
Pipe schematic from manhole 18 0206 to 18 0205
MH: 18 0206MH: 18 0205downstream0 ft. MWM - Water Mark, 90 %of cross sectional area0 ft. MWL - Water Level, 80 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:30AM8 ft. MGO - General Observation - ZOOM DOWNSTREAM8 ft. MWM - Water Mark, 90 %of cross sectional area8 ft. MWL - Water Level, 90 %of cross sectional area8.5 ft. MSA - Survey Abandoned - 90% FLOW

Observation photos (1)

  • General Observation - ZOOM DOWNSTREAM

    8 ft. - General Observation - ZOOM DOWNSTREAM

Observations (7)

DistanceCodeObservation
0MWM
8.5MSA90% FLOW
0MWL
8MGOZOOM DOWNSTREAM
8MWM
0AMH2:30AM
8MWL

Properties (5)

additional_info
ZOOM DOWNSTREAM ONLY
customer
LACSD
datetime
2019-11-09T01:06:23-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection