- Date
- 09/09/2019
- W/O
- 787674
- Weather
- Dry
- Operator/Surveyor
- J. VARGAS
- Sewer ID
- Z00791
- PipeID
- P16912
- Time
- 2:02 AM
- Certificate
- U-209-8149
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6957
- Sewer Name
- 22 BEN LOMOND TRUNK
- City
- GLENDORA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_787674_TV22006_SEP2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 22 0566
- Downstream MH
- 22 0565B
- Dir. of Survey
- Downstream
- Length Surveyed
- 276.3 ft.
- Total Length
- 276.3 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2111
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 22 0566 to 22 0565B Observation photos (2)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start