- Date
- 07/29/2019
- W/O
- 766300
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00093
- PipeID
- P08964
- Time
- 10:34 PM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6723
- Sewer Name
- B JOINT OUTFALL B - UNIT 5C
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- RFIR_WO_766300_TV16079_MAY2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- B 0452
- Downstream MH
- B 0451
- Dir. of Survey
- Downstream
- Length Surveyed
- 227.7 ft.
- Total Length
- 227.7 ft.
- Structural Index
- 3
- Structural Quick
- 3H00
- Structural Rating
- 135
- O&M Index
- 2
- O&M Quick
- 4131
- O&M Rating
- 89
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 224
Pipe schematic from manhole B 0452 to B 0451 Observation photos (4)

3.4 ft. - General Observation - MAGNEZIUM H.O COATING ATTATCHED

3.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

23.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

104.6 ft. - Roots Medium Lateral, from 02 to 05 o'clock, 10 %, within 8 inches of joint: NO