Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 10, 2019, 08:27 AM
  • 02 1263_02 1262_10102019_004004.mp4

Date
10/10/2019
W/O
792821
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00288
PipeID
P04669
Time
1:27 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7059
Sewer Name
02 MONTEREY PARK DIVERSION TRUNK
City
MONTEREY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
WO_792821_TV02100_OCT2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1263
Downstream MH
02 1262
Dir. of Survey
Downstream
Length Surveyed
285.4 ft.
Total Length
285.4 ft.
Structural Index
3
Structural Quick
3J2G
Structural Rating
252
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
256
Pipe schematic from manhole 02 1263 to 02 1262
MH: 02 1263MH: 02 1262downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 12630 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area5.4 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start70.6 ft. SSS - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Start283.1 ft. SSS - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish283.1 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish285.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1262

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.4 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    70.6 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
283.1SSS
285.4AMH02 1262
0AMH02 1263
70.6SSS
5.4SAP
0MWM
0MWL
283.1SAP

Properties (6)

additional_info
SC378659
custom_field_two
2
customer
LACSD
datetime
2019-10-10T01:27:52-07:00
documentation
PROPIPE
is_lateral_inspection
false