- Date
- 10/10/2019
- W/O
- 792821
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00288
- PipeID
- P04668
- Time
- 1:41 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7059
- Sewer Name
- 02 MONTEREY PARK DIVERSION TRUNK
- City
- MONTEREY PARK
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_792821_TV02100_OCT2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 02 1262
- Downstream MH
- 02 1261
- Dir. of Survey
- Downstream
- Length Surveyed
- 412.4 ft.
- Total Length
- 412.4 ft.
- Structural Index
- 3
- Structural Quick
- 3O2N
- Structural Rating
- 393
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 397
Pipe schematic from manhole 02 1262 to 02 1261 Observation photos (2)

2.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

34.7 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start