Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 27, 2019, 05:23 AM
  • 22 1015_22 1014_09262019_220341.mp4

Date
09/26/2019
W/O
792801
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00819
PipeID
P17384
Time
10:23 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6090
Sewer Name
22 LORAINE TRUNK
City
GLENDORA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_792801_TV22159_OCT2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 1015
Downstream MH
22 1014
Dir. of Survey
Downstream
Length Surveyed
394.6 ft.
Total Length
394.6 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
75
O&M Index
2
O&M Quick
312O
O&M Rating
163
Overall Index
2
Overall Quick
Overall Rating
238
Pipe schematic from manhole 22 1015 to 22 1014
MH: 22 1015MH: 22 1014downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 10150 ft. MWL - Water Level, 25 %of cross sectional area2 ft. MGO - General Observation - MAG COAT THROUGHOUT12.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start18.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"71.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"148 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"220.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"265.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS 100%265.4 ft. RTC - Roots Tap Connection, from 02 to 05 o'clock, 10 %267.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start316.4 ft. RFJ - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES321.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS 80%321.3 ft. RMC - Roots Medium Connection, from 02 to 05 o'clock, 10 %, within 8 inches of joint: NO355 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YESR360.1 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES372.9 ft. RTJ - Roots Tap Joint, from 03 to 05 o'clock, 10 %, within 8 inches of joint: YESR374.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"384.9 ft. RFJ - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES392.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish394 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish394.6 ft. AMH - Downstream Manhole, Survey Ends - 22 1014

Observation photos (11)

  • Upstream Manhole, Survey Begins - 22 1015

    0 ft. - Upstream Manhole, Survey Begins - 22 1015

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    12.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS 100%

    265.4 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS 100%

  • Roots Tap Connection, from 02 to 05 o'clock, 10 %

    265.4 ft. - Roots Tap Connection, from 02 to 05 o'clock, 10 %

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    267.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

    316.4 ft. - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Roots Medium Connection, from 02 to 05 o'clock, 10 %, within 8 inches of joint: NO

    321.3 ft. - Roots Medium Connection, from 02 to 05 o'clock, 10 %, within 8 inches of joint: NO

  • Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YESR

    355 ft. - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

    360.1 ft. - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Roots Tap Joint, from 03 to 05 o'clock, 10 %, within 8 inches of joint: YESR

    372.9 ft. - Roots Tap Joint, from 03 to 05 o'clock, 10 %, within 8 inches of joint: YESR

  • Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

    384.9 ft. - Roots Fine Joint, from 04 to 08 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
355RFJ
184.4TFA
392.4SAV
394.6AMH22 1014
374.2TFA
148TF
267.4SAV
321.3TFAROOTS 80%
394DAGS
0MWM
0AMH22 1015
220.7TFC
384.9RFJ
18.6TFA
316.4RFJ
265.4TFROOTS 100%
372.9RTJ
321.3RMC
12.1DAGS
265.4RTC
360.1RFJ
2MGOMAG COAT THROUGHOUT
0MWL
71.2TF

Properties (6)

additional_info
SC378437
custom_field_two
3
customer
LACSD
datetime
2019-09-26T22:23:03-07:00
documentation
PRO PIPE
is_lateral_inspection
false