Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2019, 09:03 AM
  • E 0126_G 0094_10032019_020827.mp4

Date
10/03/2019
W/O
787679
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00027
PipeID
P07608
Time
2:03 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7055
Sewer Name
E JOINT OUTFALL E - UNIT 1
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_787679_TV30070_SEP2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
E 0126
Downstream MH
G 0094
Dir. of Survey
Downstream
Length Surveyed
16.7 ft.
Total Length
16.7 ft.
Structural Index
4
Structural Quick
5132
Structural Rating
11
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
17
Pipe schematic from manhole E 0126 to G 0094
MH: E 0126MH: G 0094downstream0 ft. MGO - General Observation - CONNECTION AT 3 O'CLOCK0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start0 ft. AMH - Upstream Manhole, Survey Begins - E 01260 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area4.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.4 ft. MGO - General Observation - MAG COATING THROUGHOUT PIPE14.2 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO16.7 ft. MGO - General Observation - CONNECTION AT 3 O'CLOCK STOPLOG16.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish16.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish16.7 ft. AMH - Downstream Manhole, Survey Ends - G 0094

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

    14.2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

Observations (12)

DistanceCodeObservation
14.2SRV
7.4MGOMAG COATING THROUGHOUT PIPE
16.7MGOCONNECTION AT 3 O'CLOCK STOPLOG
0MGOCONNECTION AT 3 O'CLOCK
0DAGS
0AMHE 0126
16.7SAP
4.8SAP
16.7DAGS
0MWM
0MWL
16.7AMHG 0094

Properties (6)

additional_info
SC378655
custom_field_two
2
customer
LACSD
datetime
2019-10-03T02:03:58-07:00
documentation
PROPIPE
is_lateral_inspection
false