Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 27, 2019, 05:52 AM
  • 14 0308A_14 0308_08262019_225740.mp4

Date
08/26/2019
W/O
782143
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00583
PipeID
P18376
Time
10:52 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6883
Sewer Name
14 TRUNK "F"
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_782143_TV14028_AUG2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
14 0308A
Downstream MH
14 0308
Dir. of Survey
Downstream
Length Surveyed
43.1 ft.
Total Length
43.1 ft.
Structural Index
3
Structural Quick
3828
Structural Rating
40
O&M Index
2
O&M Quick
2800
O&M Rating
16
Overall Index
2
Overall Quick
Overall Rating
56
Pipe schematic from manhole 14 0308A to 14 0308
MH: 14 0308AMH: 14 0308downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 14 0308A2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COATING THROUGHOUT2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start41.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish41.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish41.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish43.1 ft. AMH - Downstream Manhole, Survey Ends - 14 0308

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - MAG COATING THROUGHOUT

    2.1 ft. - General Observation - MAG COATING THROUGHOUT

Observations (13)

DistanceCodeObservation
2DAGS
41.4SAP
41.4DAGS
41.4SSS
0MWM
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWL
2.1SSS
0MGOCOCKROACHES IN MANHOLE
2.1MGOMAG COATING THROUGHOUT
43.1AMH14 0308
2.1SAP
0AMH14 0308A

Properties (6)

additional_info
SC378468
custom_field_two
3
customer
LACSD
datetime
2019-08-26T22:52:18-07:00
documentation
PRO PIPE
is_lateral_inspection
false