Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 6, 2019, 10:34 AM
  • 15 0778_15 0777_1162019_023823.mp4

Date
11/06/2019
W/O
0793083
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P12979
Time
2:34 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1300R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Maintenance Related
Project
20191106MDM_ARACIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0778
Downstream MH
15 0777
Dir. of Survey
Downstream
Length Surveyed
385.6 ft.
Total Length
385.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 15 0778 to 15 0777
MH: 15 0778MH: 15 0777downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 2:35AM30.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open63.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open91 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped99.6 ft. RTC - Roots Tap Connection, from 01 to 02 o'clock, 10 %, within 8 inches of joint: YES99.6 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open-98% ROOTS124.3 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open=80% ROOTS152 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open257.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open267.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open303.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped306.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open356 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open385 ft. MGO - General Observation - MH CONN 3:00 ACTIVE385.6 ft. AMH - Downstream Manhole, Survey Ends - 3:00AM

Observation photos (1)

  • Roots Tap Connection, from 01 to 02 o'clock, 10 %, within 8 inches of joint: YES

    99.6 ft. - Roots Tap Connection, from 01 to 02 o'clock, 10 %, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
63.6TFOpen
267.4TFOpen
99.6RTC
385.6AMH3:00AM
257.9TFOpen
99.6TFDOpen-98% ROOTS
0MWL
124.3TFDOpen=80% ROOTS
385MGOMH CONN 3:00 ACTIVE
0MWM
303.7TFCCapped
152TFOpen
30.6TFOpen
91TFCCapped
306.6TFOpen
0MGOMH CONN 3:00 ACTIVE
0AMH2:35AM
356TFOpen

Properties (5)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-11-06T02:34:38-08:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false