16 0572_16 0571_1152019_100655.mp4
8.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
12.9 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
16 ft. - Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - ROOT MATTING
37.6 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4" - TAP ROOT
84.4 ft. - Roots Tap Barrell, from 12 to 06 o'clock, 5 %, within 8 inches of joint: YES
86.3 ft. - General Photograph - TAP ROOTS
90.8 ft. - Roots Tap Barrell, at 12 o'clock, 5 %, within 8 inches of joint: NO
135.7 ft. - Roots Tap Barrell, at 10 o'clock, 80 %, within 8 inches of joint: NO
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 10:30 AM |
| 90.8 | RTB | — |
| 257.3 | DAZ | — |
| 16 | DAZ | ROOT MATTING |
| 0 | MWM | — |
| 8.2 | SAP | — |
| 163.7 | RTL | — |
| 84.4 | RTB | — |
| 257.3 | SAP | — |
| 184.6 | RML | — |
| 257.3 | SRV | — |
| 258.6 | AMH | 10:33AM |
| 0 | MWL | — |
| 37.6 | TFD | TAP ROOT |
| 12.9 | SRV | — |
| 86.3 | MGP | TAP ROOTS |
| 135.7 | RTB | — |