Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 30, 2019, 12:07 PM
  • 17 0827_17 0826_10302019_050925.mp4

Date
10/30/2019
W/O
073082
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P13028
Time
5:07 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1291R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
SIERRA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
20191030MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
9.420000076293945 in.
Upstream MH
17 0827
Downstream MH
17 0826
Dir. of Survey
Downstream
Length Surveyed
297.4 ft.
Total Length
297.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3200
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 17 0827 to 17 0826
MH: 17 0827MH: 17 0826downstream0 ft. AMH - Upstream Manhole, Survey Begins - 5:10AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area12.4 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - Open-95% ROOTS12.4 ft. RML - Roots Medium Lateral, at 10 o'clock, 5 %, within 8 inches of joint: NO18.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open36.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open84 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open121.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open133 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open157.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active201.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open225.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open293 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open297.4 ft. AMH - Downstream Manhole, Survey Ends - 5:30AM

Observations (15)

DistanceCodeObservation
0AMH5:10AM
18.3TBOpen
293TBOpen
36.2TBOpen
225.9TBOpen
157.5TBActive
0MWM
12.4TBDOpen-95% ROOTS
0MWL
201.4TBOpen
133TBOpen
12.4RML
121.3TBOpen
84TBOpen
297.4AMH5:30AM

Properties (6)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-10-30T05:07:04-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
CIPP