Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 25, 2019, 05:15 PM
  • 05 1804A_05 1804_10252019_101805.mp4

Date
10/25/2019
W/O
0799737
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00466
PipeID
P07027
Time
10:15 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
G81111
Sewer Name
05 JANET LANE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
31
Purpose
Maintenance Related
Project
20191025DF_JANET_LANE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
05 1804A
Downstream MH
05 1804
Dir. of Survey
Downstream
Length Surveyed
87.9 ft.
Total Length
87.9 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
2
O&M Quick
3111
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 05 1804A to 05 1804
MH: 05 1804AMH: 05 1804downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:17 AM0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR - 5%58 ft. MGP - General Photograph59.3 ft. MGP - General Photograph60.2 ft. TBI - Tap Break-In Intruding, at 09 o'clock, -, -, within 8 inches of joint: YES, 4", 2" - DEFECTIVE/5% ROOTS/OPEN76.2 ft. B - Broken, at 05 o'clock, within 8 inches of joint: YES85.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish85.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish87.9 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)87.9 ft. AMH - Downstream Manhole, Survey Ends - 10:29 AM

Observation photos (7)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR - 5%

    32.4 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR - 5%

  • General Photograph

    58 ft. - General Photograph

  • General Photograph

    59.3 ft. - General Photograph

  • Tap Break-In Intruding, at 09 o'clock, -, -, within 8 inches of joint: YES, 4", 2" - DEFECTIVE/5% ROOTS/OPEN

    60.2 ft. - Tap Break-In Intruding, at 09 o'clock, -, -, within 8 inches of joint: YES, 4", 2" - DEFECTIVE/5% ROOTS/OPEN

  • Broken, at 05 o'clock, within 8 inches of joint: YES

    76.2 ft. - Broken, at 05 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
59.3MGP
0AMH10:17 AM
60.2TBIDEFECTIVE/5% ROOTS/OPEN
87.9MGOGREASE THROUGHOUT THE REACH (5%)
2CM
85.6SSS
85.6CM
2SSS
58MGP
0MWL
87.9AMH10:29 AM
32.4RFJ5%
0MWM
76.2B

Properties (6)

additional_info
POST ROOT EVALUATION ONLY
custom_field_two
3
customer
LACSD
datetime
2019-10-25T10:15:54-07:00
documentation
FRANKLIN, BRAR, RUVALCABA, SHADLER
is_lateral_inspection
false