Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 10, 2019, 08:00 AM
  • 14 1117_14 1116_10102019_010907.mp4

Date
10/10/2019
W/O
787589
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01179
PipeID
P26069
Time
1:00 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7031
Sewer Name
14 WEST SIDE RELIEF TRUNK
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
10
Purpose
Routine Assessment
Project
WO_787589_TV14056_SEP2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
14 1117
Downstream MH
14 1116
Dir. of Survey
Downstream
Length Surveyed
255.9 ft.
Total Length
255.9 ft.
Structural Index
2
Structural Quick
2I00
Structural Rating
100
O&M Index
2
O&M Quick
2I00
O&M Rating
100
Overall Index
2
Overall Quick
Overall Rating
200
Pipe schematic from manhole 14 1117 to 14 1116
MH: 14 1117MH: 14 1116downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 11170 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN65.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN254 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish254.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish255.9 ft. MGO - General Observation - CONN 9 O'CLOCK @ MH/ACTIVE255.9 ft. AMH - Downstream Manhole, Survey Ends - 14 1116255.9 ft. MGO - General Observation - CONN 3 O'CLOCK @ MH/OPEN

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
2DAGS
0MWM
255.9MGOCONN 9 O'CLOCK @ MH/ACTIVE
65.1TFOPEN
0AMH14 1117
10.2TFOPEN
255.9AMH14 1116
254SSS
255.9MGOCONN 3 O'CLOCK @ MH/OPEN
0MWL
2SSS
254.3DAGS
0MGOCONN @ MH 3 O'CLOCK/ACTIVE

Properties (7)

additional_info
SC378650
custom_field_two
4
customer
LACSD
datetime
2019-10-10T01:00:40-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
40175