- Date
- 09/12/2019
- W/O
- 787653
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00204
- PipeID
- P02096
- Time
- 3:38 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6929
- Sewer Name
- 01 COMPTON CREEK EXTENSION TRUNK, SECTION 2
- City
- LOS ANGELES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- RFIR_WO_787653_TV01272_SEP2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 01 0152
- Downstream MH
- 01 0153
- Dir. of Survey
- Upstream
- Length Surveyed
- 330.4 ft.
- Total Length
- 330.4 ft.
- Structural Index
- 3
- Structural Quick
- 4222
- Structural Rating
- 12
- O&M Index
- 2
- O&M Quick
- 4121
- O&M Rating
- 7
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 19
Pipe schematic from manhole 01 0152 to 01 0153 Observation photos (6)

6.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

12.2 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

32.9 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

66.5 ft. - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

72.7 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

76.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start