Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 16, 2019, 05:08 AM
  • 02 0862_02 0861_10152019_220836.mp4

Date
10/15/2019
W/O
787659
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00297
PipeID
P03429
Time
10:08 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7038
Sewer Name
02 OLD RIVER SCHOOL ROAD RELIEF TRUNK, SECTS 2&3
City
DOWNEY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_787659_TV02299_SEP2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
02 0861
Downstream MH
02 0862
Dir. of Survey
Upstream
Length Surveyed
643.5 ft.
Total Length
643.5 ft.
Structural Index
3
Structural Quick
3Y2Y
Structural Rating
640
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
640
Pipe schematic from manhole 02 0861 to 02 0862
MH: 02 0861MH: 02 0862upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 08621.5 ft. MGO - General Observation - PEELING AND FLAKING THROUHGOUT2.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3.5 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 90% MAG436.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN641.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start641.5 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 90% MAG641.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start643.5 ft. MWM - Water Mark, 30 %of cross sectional area643.5 ft. AMH - Downstream Manhole, Survey Begins - 02 0861643.5 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (2)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
643.5AMH02 0862
641.1SAP
0MWM
2SSS
206.7TFOPEN
2SZ90% MAG
640SZ90% MAG
642MGOPEELING AND FLAKING THROUHGOUT
2SAP
0AMH02 0861
0MWL
641.1SSS

Properties (6)

additional_info
SC378707
custom_field_two
2
customer
LACSD
datetime
2019-10-15T22:08:33-07:00
documentation
PRO PIPE
is_lateral_inspection
false