16 0197_16 0196_10022019_234606.mp4

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

9 ft. - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

13 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start
86.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES
106.2 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS
106.3 ft. - Roots Fine Connection, from 12 to 06 o'clock

167 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"
173.6 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 01 to 04 o'clock, , within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 181.5 | MGO | MAG COAT THROUGHOUT END |
| 0 | MWL | — |
| 9 | SRI | — |
| 86.1 | DAE | — |
| 183 | SAV | — |
| 173.6 | DAE | — |
| 167 | TF | — |
| 181.5 | DAGS | — |
| 106.2 | TFA | ROOTS |
| 13.3 | MGO | MAG COAT THROUGHOUT |
| 106.3 | RFC | — |
| 0 | MWM | — |
| 2 | DAGS | — |
| 183 | SRI | — |
| 13 | SAV | — |
| 0 | AMH | 16 0197 |
| 183.6 | AMH | 16 0196 |