Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2019, 06:59 AM
  • 16 0196_16 0195_10032019_001130.mp4

Date
10/02/2019
W/O
787582
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00647
PipeID
P13241
Time
11:59 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
k6093
Sewer Name
16 ARROYO SECO TRUNK, SECTION 4
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
WO_787662_TV16012_SEP2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
16 0196
Downstream MH
16 0195
Dir. of Survey
Downstream
Length Surveyed
210.8 ft.
Total Length
210.8 ft.
Structural Index
2
Structural Quick
3G2G
Structural Rating
199
O&M Index
2
O&M Quick
2X00
O&M Rating
248
Overall Index
2
Overall Quick
Overall Rating
447
Pipe schematic from manhole 16 0196 to 16 0195
MH: 16 0196MH: 16 0195downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 01960 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COAT THROUGHOUT5 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start5 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Start5.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start13.1 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start59.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"109.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"179 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"209.6 ft. MGO - General Observation - MAG COAT THROUGHOUT END210 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish210 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish210 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish210 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Finish210.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish210.8 ft. AMH - Downstream Manhole, Survey Ends - 16 0195

Observation photos (9)

  • Upstream Manhole, Survey Begins - 16 0196

    0 ft. - Upstream Manhole, Survey Begins - 16 0196

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    5 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 10 to 02 o'clock,  , within 8 inches of joint: YES, Start

    5 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    5.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    13.1 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    59.4 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    109.8 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    179 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (19)

DistanceCodeObservation
0MWM
210SAV
210SSS
210.6DAGS
59.4TFA
5.4DAGS
179TFA
109.8TFC
0MWL
5SSS
13.1SAV
0AMH16 0196
5DAE
0DAGS
210.8AMH16 0195
210DAGS
210DAE
2MGOMAG COAT THROUGHOUT
209.6MGOMAG COAT THROUGHOUT END

Properties (6)

additional_info
SC378440
custom_field_two
3
customer
LACSD
datetime
2019-10-02T23:59:21-07:00
documentation
PRO PIPE
is_lateral_inspection
false