- Date
- 10/03/2019
- W/O
- 787582
- Weather
- Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00647
- PipeID
- P13240
- Time
- 12:17 AM
- Certificate
- U-109-7948
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- k6093
- Sewer Name
- 16 ARROYO SECO TRUNK, SECTION 4
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_787662_TV16012_SEP2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 16 0195
- Downstream MH
- 16 0179
- Dir. of Survey
- Downstream
- Length Surveyed
- 87.4 ft.
- Total Length
- 87.4 ft.
- Structural Index
- 3
- Structural Quick
- 3B2B
- Structural Rating
- 85
- O&M Index
- 2
- O&M Quick
- 2B00
- O&M Rating
- 32
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 117
Pipe schematic from manhole 16 0195 to 16 0179 Observation photos (5)

0 ft. - Upstream Manhole, Survey Begins - 16 0195

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

3 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

4.1 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

31.9 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"