02 0366A_02 0366 _07182019_011928.mp4
4.5 ft. - Deposits Settled Compacted, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
5.1 ft. - Crack Spiral, from 08 to 04 o'clock, within 8 inches of joint: YES
9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
14.2 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: NO
14.8 ft. - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - COLLAPSED/VOID
14.8 ft. - Hole Void Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - AT CONNECTION
110.4 ft. - Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES
113.2 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES
211.6 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 299.9 | CM | — |
| 211.6 | FL | — |
| 21.6 | TBC | — |
| 4.5 | DSC | — |
| 9 | CM | — |
| 14.8 | TBD | COLLAPSED/VOID |
| 0 | MWL | — |
| 0 | MGO | SERVICE CONNECTION AT 9 O'CLOCK AT MH |
| 113.2 | FS | — |
| 173.5 | TB | — |
| 213.5 | TB | — |
| 0 | AMH | 02 0366A |
| 275.1 | TFC | — |
| 111.7 | TF | — |
| 65.3 | TBC | — |
| 228.2 | TBC | — |
| 162.6 | TF | — |
| 14.2 | FL | — |
| 0 | VC | — |
| 76.6 | TBC | — |
| 0 | MWM | — |
| 5.1 | CS | — |
| 300 | DSC | — |
| 301.1 | AMH | 02 0366 |
| 14.8 | HVV | AT CONNECTION |
| 110.4 | FM | — |
| 127.4 | TB | — |
| 263.8 | TB | — |