- Date
- 09/11/2019
- W/O
- 787496
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00571
- PipeID
- P18155
- Time
- 12:06 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6891
- Sewer Name
- 14 DISTRICT #14 OUTFALL TRUNK
- City
- LANCASTER
- Loc. details
- Alley
- Location Code
- H
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- RFIR_WO_787496_TV14066_SEP2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 14 0124
- Downstream MH
- 14 0125
- Dir. of Survey
- Upstream
- Length Surveyed
- 104.5 ft.
- Total Length
- 104.5 ft.
- Structural Index
- 3
- Structural Quick
- 3C00
- Structural Rating
- 54
- O&M Index
- 2
- O&M Quick
- 312C
- O&M Rating
- 43
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 97
Pipe schematic from manhole 14 0124 to 14 0125 Observation photos (5)

0 ft. - Downstream Manhole, Survey Begins - 14 0124, ABANDONED MH.

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

13.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

52 ft. - Water Level, 50 %of cross sectional area

104.5 ft. - Survey Abandoned - DUE TO DEBRIS. REVERSAL COMPLETE.